@@ -0,0 +1,24 @@
|
||||
# Collider Diagnostics Acceptance
|
||||
|
||||
Issue: Gitea #26 (`BS-JD-305`)
|
||||
|
||||
## Evidence
|
||||
|
||||

|
||||
|
||||
The native Wayland editor loaded `assets/levels/collider_diagnostics_showcase.scn.ron` and entered
|
||||
Collider view. The captured frame shows shape overlays with meshes hidden, the scene health HUD,
|
||||
the selectable Diagnostics window, and the selected trigger's hydrated status in the inspector.
|
||||
|
||||
## Live Results
|
||||
|
||||
- Box, scaled sphere/ellipsoid, and capsule overlays matched authored transforms and dimensions.
|
||||
- Green ready, cyan trigger, gray disabled, and red missing states were visually distinct.
|
||||
- The HUD reported `4 ready / 1 disabled / 0 warning / 1 invalid` and followed selection.
|
||||
- The Diagnostics panel linked the missing finding back to its actor.
|
||||
- Switching the valid box to sphere preserved useful extents and produced `Undo: Set Collider`;
|
||||
undo restored the box.
|
||||
- Physics Placement rejected the missing-collider actor with the shared collider-health messages.
|
||||
- Scene switching and editor shutdown completed without a panic or runtime validation error.
|
||||
|
||||
Packaged verification remains deferred by current project instruction.
|
||||